| - KCD2-SCD-Ex1
SMART Current Driver -
| | 1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.1 %, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 |
|
| - KFD0-CS-Ex1.51P
Current Driver/Repeater -
| | 1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex protection, Transfer direction: to the field / to the control system |
|
| | | 1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex protection, Transfer direction: to the field / to the control system |
|
| - KFD2-SCD-Ex1.LK
SMART Current Driver -
| | 1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508 |
|
| - KFD2-SCD2-Ex1.LK
SMART Current Driver -
| | 1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.05 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508 |
|
| - KFD2-SCD2-Ex2.LK
SMART Current Driver -
| | 2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.05 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508 |
|
| - KCD2-SCD-Ex1.SP
SMART Current Driver -
| | 1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.1 %, Housing width 12.5 mm, Connection via spring terminals, Up to SIL 2 acc. to IEC 61508 |
|
| | | 1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex protection, Transfer direction: to the field / to the control system |
|
| - KFD0-CS-Ex1.53
Current Driver -
| | 1-channel isolated barrier, DC supply (loop powered), Current input/output 0 mA ... 40 mA, Accuracy 1 %, Low voltage drop, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Transfer direction: to the field |
|
| | | 2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex protection, Transfer direction: to the field / to the control system |
|